It may facilitate the user by graphically to access, examine, setting, change and confirm each kind of control parameter value from B-AAC/B-ASC controller, for example temperature value, humidity value, devices operation status, and alarm messages, enable output points start/stop, changing the temperature and humidity setting values,etc. NVT70PE has a 7 inches TFT LCD touch screen and Simplified / Traditional Chinese / English display subtitles function, four function keys, build in with a 32-bit high performance microprocessor. User can use BACsoft software or HMIkit to edit their favorite display screen pages, even corporate image or promotion leaflet can be loaded to the screen when in non operation mode, this not only enhance the added value of products but also enhance the effectiveness of corporate image advertising.
Description
- BTL listed BACnet Operator Display (B-OD) panel.
- ommunication interface can be either BACnet Ethernet or the BACnet/IP or BACnet MS/TP communication protocol.
- BACnet MS/TP interface with 2500Vrms electrical isolated protection and TVS ARRAY surge protection that can effectively avoid network abnormality signal influences, communication speed from 9.6 to 76.8 Kbps, maximum length 1,200 meters.
- 7.0” screen, 262K colors, touch screen TFT LCD, 800*480 pixel, set up with AIRTEK BACsoft software. Can support up to 65,536 colors.
- Selectable simplified Chinese, Traditional Chinese, and English, UTF-8 fonts, simplified and traditional Chinese can be displayed on the same screen graphic.
- Four + F1 + F2 + F3 function keys, is system setup key. F1, F2, and F3 can be set up as function keys for switch display pages.
- Update firmware and upload graphic pages by using a Mini USB cable.
- 128M Bytes fonts and graphic memory. It can hold numerous pages display graphic. Actual pages depend on data size.
- The panel can read property of a BACnet device on the network. The reading property can be logic, value, list, string, object, time, date, or list status of a bit string.
- Display incoming alarm notification messages from any device on the network. Most recent 80 messages will be stored in the message history.
- The panel can modify Calendar、Schedule that any B-AAC&B-BC device on the BACnet Ethernet network, compliant to SCHED-VM-A (BIBB – Scheduling-View and Modify-A)
- 10 password levels, users can setup up to 20 passwords.
- Has a BACnet MS/TP network communication quality monitor function.
- Time synchronizes function. Selectable to broadcast on the BACnet network.